(1-15KVA)
|
|
FEATURES
 |
Fax
|
 |
Voice Message for Alarm Condition
|
 |
E-mail
|
 |
Pager
|
 |
Alpha Pager
|
 |
Modem
|
|
|
|
|
|
 |
|
STANDARD FEATURES
|
Monitor |
in real time graphic
 |
 |
Inputs |
8 universal inputs - the status tab shows name, value, status, unit of measure and min / max values.
 |
 |
Data Logs |
The data logger can log up to 32,768 input readings
 |
 |
Reports |
Any report logged by the system can be stored or sent via e-mail or fax by location and by time of day.
 |
 |
Polling Mode |
This item will allow your PC to communicate automatically with multi Monitor 2000 units. Polling is a process of calling units to retrieve the data log or event log.
 |
 |
Auto Answer |
This item, auto answer allow your PC to receive alarm calls when the destination type is set to modem.
 |
 |
Destinations |
This item will call up to 32 telephone numbers or e-mail address to report the alarm conditions or to send reports.
 |
 |
Unit Scheduler |
This allows you to use the data log and event log and tie the information into the daily log.
 |
 |
Events |
The event logger displays all events that have occurred over a total period of time or just a selected period of time.
 |
 |
System |
This is the screen that has all the pertinent information such as unit phone numbers, date, dial-out, settings, access acknowledgement code, password and incoming call settings.
 |
 |
Programming |
This unit can be programmed via a local serial port or remotely by modem using an IBM compatible computer with the Windows Operating System. This is included in the Monitor 2000 software package.
 |
 |
This Windows based universal piece of equipment is not limited to the electronic Industry. It can monitor equipment and environmental conditions using 8 universal inputs plus built power failure detection. The Monitor 2000 also features a wide variety of communication options,
such as:
 |
|
User Recordable Voice
|
|
Fax
|
|
Modem
|
|
Numeric Pager
|
|
Alpha Numeric Page
|
|
Internet e-mail
|
 |
|
|
SPECIFICATION
|
 |
| Sizes: |
 |
Mini: 1, 1.5, 2, 2.5, 3 kVA
Max: 3, 5, 8, 10, and 15 kVA
|
 |
| Input Voltage: |
|
120 or 208,220,240 or 480 VAC |
 |
| Output Voltage: |
|
120, or 120/240 VAC |
 |
| Frequency: |
|
60 Hz. +5%
|
 |
| Transformer Type: |
|
Single phase computer grade, dual-shielded, isolation transformer |
| Efficiency: |
|
96% |
| Load Power Factor: |
|
3 leading or lagging to unity |
| Harmonic Distortion at Switching: |
|
1% Max. |
| Audible Noise: |
|
<35 dB. Measured on response curve "A"
Audible Noise: Typical Noise Refection
Common-mode; -120 dB.
Normal-mode; -60 dB/decade
Input Voltage Regulation Range
Mini; +7% to -23% of nominal
Max; +10% to -26% of norminal
Output Voltage Regulation Range
Mini: +5% typ. +5% all line-load cond.
Max: +3% typ. +4% all line load cond.
|
| Cooling: |
|
Convection
|
| Response Time: |
|
1 Cycle typical
|
| Loading Rating: |
|
Continuous, regardless of load/line cond.
|
| Overall Inrush Rating: |
|
200% at 10 seconds; 1000% at 1 cycle
|
| Operating Temperature: |
|
32?F. (0?C.) to 104?F. (40?C.)
|
 |
| Storage Temperature: |
|
-4?F. (-20?C.) to 140?F. (60?C.)
|
 |
| Operating Humidity: |
|
10 to 95% Non-Condensation
|
 |
| Dimension: |
|
Mini Series: 12?H x 6.5?W x 12?D
Max Series: 19.5?H x14.5?W x25.5??D
|
 |

|
|
|