2.1 kW TO 17 kw

DOUBLE CONVERSION, FAST TRANSFER OR STAND BY SYSTEMS AVAILABLE TO POWER ALL LAMP TYPES INCLUDING LED and HID

LED, HID, Incandescent, Fluorescent

Installed in Office Buildings, Factories, Hospitals, School, Shopping Centers, Casinos, Airports, Train and Bus Terminals

WAVE RIDER 1

FEATURES

CSA Listed to UL924 & UL1778
Compact, each units in one cabinet
LED, Incandescent, Fluorescent, HID, HPS
Power Factor & Energy Efficient Ballast
92 - 98% Efficiency
Sinusoidal wave
Pulse width modulated (PWM)
Generator compatible
Multiple Output Voltages
LCD panel for monitoring of continuous self diagnostic
Modular Assembly for Ease of Installation
Transformerless Technology
Battery exerciser
Double Conversion Technology or Fast Transfer
Seismic rated with bracket kit.
Stackable Cabinets
RS 232 & RS 485
Global Monitoring System Option

 

SPECIFICATIONS

Power Rating 2.1, 3, 5, 6, 8, 10, 12.5, 15 and 17 kW
Input Voltage 2.1 - 5KW, 6KW; 120, 208, 240, 277, or 480 VAC (-15% to +10%)
8 - 17KW; 208, 240, 277, or 480 VAC (-15% to +10%)
Output Voltage 120, 208, 240, 277, or 480 VAC. 120/240: 120/208; 120/277; 480 & 277
Output Frequency Inverter Operation: : 60Hz ±0.5Hz
Voltage Regulation ±3% Typical
Output Waveform Sine-wave
Optional Input Protection Input Circuit Breaker provided protection to the unit, load, and personnel and is rated at (10 KAIC) standard, higher interruption up to 65 (KAIC) optional.
Output Protection Internal Electronic overload protection. Circuit breaker provides inherent over-load protection. Factory selectable voltage 120, 208, 240, 277, or 480 for input or output voltages. If input is different from output or output different from input, an internally mounted transformer is required.
Surge Protection The inverter will protect itself and the load against surge as defined in ANSI/IEEE C62.45 category A and B.
Noise Isolation -120 dB. Common-Mode., 60 dB. Transverse-Mode
Isolation Output is completely isolated from input and with multi voltages.
Efficiency 98% standby - fast transfer / 94% online
Power Factor Unity
Crest Factor 3.1
Battery Sealed, Maintenance-free, Lead-Acid, VRLA (Standard) 10 years
Battery Management System Utilizes a microprocessor technology to monitor the batteries critical levels and apply charging cycles in a method to substantially increase battery life.
Battery Housing Free-standing NEMA 1 enclosure with powder-coated finish; front access only; multiple conduit entry points; see dimension chart.
Recharge Time Conforms to UL924
Environmental

Humidity: 0-95% w/ no condensation
Operating Temperature:
UPS: 0°C to 40°C. (32°F to 104°F)
Battery: 20°C to 25°C. (68°F to 77°F)
Storage temperature: -20°C to 70°C. (-4°F to 158°F)

Safety Agencies CSA Listed to UL924, UL924A, & UL1778
Dimension 2.1 - 3 kW (optional): 39" Wide x 48" High x 18" Deep
2.1 - 8 kW: 39" Wide x 68" High x 18" Deep
10 - 17 kW: 51" Wide x 70" High x 30.5" Deep

 

Document Files
Document Type PDF format Word Format
DatasheetDatasheet
Design Guide SpecDesign Guide SpecDesign Guide Spec
ManualManual
Tech DrawingsTech Drawings
Seismic BracketSeismic Bracket
OptionsOptionsOptions
STP/CAD Files

Standard

Cabinet TypeKVA / SizeMountingFile
Inverter CabinetB SizeStandardSTP
Inverter CabinetC SizeStandardSTP
Inverter CabinetD SizeStandardSTP

With Seismic

Cabinet TypeKVA / SizeMountingFile
Inverter CabinetB SizeWith SeismicSTP
Inverter CabinetC SizeWith SeismicSTP
Inverter CabinetD SizeWith SeismicSTP